Manual Extract: Loader bucket control cylinder – Disassemble

2. Drain the engine coolant.
3. Locate the DEF/ADBLUE® Heater Control valve up to Supply Module on the right–hand side of the engine.
4. Disconnect the machine wiring harness (2) from the DEF/ADBLUE® heater control valve.
Using a small flat blade screw driver, pull up on the fitting retaining clip and disconnect the coolant inlet (3) /outlet (5) and by-pass (4) lines from the heater control valve (1)
5. Remove the hexagonal bolts (6) securing heater control valve to the mounting support bracket and remove the heater control valve (1) from machine.