Manual Extract: Cooling fan belt adjustment

• Loosen the adjust plate lock bolt and the mounting bolt at the bottom side of the generator (3).
• Turn the adjust bolt (4) to adjust the belt.
• Press the specified position on the belt with the specified load to inspect the amount of belt flex (7).
Load: 98 N (22 lb)
• Verify whether precise tension has been set using a sonic tension meter.
Amount of deflection
New: 4.2 – 5.0 mm (0.1654 – 0.1969 in) When adjusting the tension: 6.6 – 7.4 mm (0.2598 – 0.2913 in)
Frequency of vibrations
New: 220 – 244 Hz
When adjusting the tension: 182 – 206 Hz 1. Crankshaft pulley
2. Installation bolt
5. Lock nut
6. Fan pulley